Starting from the structured dose reports (DSR) saved on the PACS of the Vercelli hospital, individual dosimetric assessments were performed with the Monte Carlo method, using the PCXMC program, in 100 consecutive interventional cardiology procedures, conducted with digital angiographs. Starting from the evaluations of effective dose and dose to organs, the conversion coefficients between effective dose / dose to organs were determined with the product KERMA by area, recorded on the DSR. Differences with similar values published in scientific literature for different devices were then evaluated in order to determine the generalizability of the estimate of effective dose / organ dose.

A partire dai report di dose strutturati (DSR) salvati sui PACS dell’Ospedale di Vercelli sono state eseguite valutazioni dosimetriche individuali con Metodo Monte Carlo, utilizzando il programma PCXMC, in 100 procedure consecutive di cardiologia interventistica, condotte con angiografi digitali. A partire dalle valutazioni di Dose efficace e di dose agli organi sono stati determinati i coefficienti di conversione fra dose efficace/dosi agli organi con il prodotto KERMA per area, registrato sul DSR. Sono state poi valutate differenze con valori simili pubblicati in letteratura scientifica per apparecchiature diverse al fine di determinare la generalizzabilità della stima di dose efficace/dose agli organi.

Determinazione dei fattori di conversione Dose efficace/Prodotto KERMA Area in procedure di cardiologia interventistica

STURA, GIULIA
2020/2021

Abstract

A partire dai report di dose strutturati (DSR) salvati sui PACS dell’Ospedale di Vercelli sono state eseguite valutazioni dosimetriche individuali con Metodo Monte Carlo, utilizzando il programma PCXMC, in 100 procedure consecutive di cardiologia interventistica, condotte con angiografi digitali. A partire dalle valutazioni di Dose efficace e di dose agli organi sono stati determinati i coefficienti di conversione fra dose efficace/dosi agli organi con il prodotto KERMA per area, registrato sul DSR. Sono state poi valutate differenze con valori simili pubblicati in letteratura scientifica per apparecchiature diverse al fine di determinare la generalizzabilità della stima di dose efficace/dose agli organi.
ITA
Starting from the structured dose reports (DSR) saved on the PACS of the Vercelli hospital, individual dosimetric assessments were performed with the Monte Carlo method, using the PCXMC program, in 100 consecutive interventional cardiology procedures, conducted with digital angiographs. Starting from the evaluations of effective dose and dose to organs, the conversion coefficients between effective dose / dose to organs were determined with the product KERMA by area, recorded on the DSR. Differences with similar values published in scientific literature for different devices were then evaluated in order to determine the generalizability of the estimate of effective dose / organ dose.
IMPORT DA TESIONLINE
File in questo prodotto:
File Dimensione Formato  
753534_stura_tm.pdf

non disponibili

Tipologia: Altro materiale allegato
Dimensione 4.11 MB
Formato Adobe PDF
4.11 MB Adobe PDF