The R3B collaboration at the GSI laboratory performs studies regarding nuclear structure and the dynamics of nuclear reactions, using unstable nuclei. A main component of the setup that will be used for such studies is the neutron detector NeuLAND, which performs high resolution measurements of time and position of relativistic neutrons, adding also calorimetric properties. The measurements of time and energy need to be properly calibrated. This thesis describes the algorithm used to find the parameters for the calibration. The data used for this purpose have been obtained during the SOFIA experiment, a test experiment with a demonstrator (i.e. part of) NeuLAND.
The R3B collaboration at the GSI laboratory performs studies regarding nuclear structure and the dynamics of nuclear reactions, using unstable nuclei. A main component of the setup that will be used for such studies is the neutron detector NeuLAND, which performs high resolution measurements of time and position of relativistic neutrons, adding also calorimetric properties. The measurements of time and energy need to be properly calibrated. This thesis describes the algorithm used to find the parameters for the calibration. The data used for this purpose have been obtained during the SOFIA experiment, a test experiment with a demonstrator (i.e. part of) NeuLAND.
Calibration of the NeuLAND detector for the R3B experiment at GSI
PELIZZA, ALBERTO
2014/2015
Abstract
The R3B collaboration at the GSI laboratory performs studies regarding nuclear structure and the dynamics of nuclear reactions, using unstable nuclei. A main component of the setup that will be used for such studies is the neutron detector NeuLAND, which performs high resolution measurements of time and position of relativistic neutrons, adding also calorimetric properties. The measurements of time and energy need to be properly calibrated. This thesis describes the algorithm used to find the parameters for the calibration. The data used for this purpose have been obtained during the SOFIA experiment, a test experiment with a demonstrator (i.e. part of) NeuLAND.File | Dimensione | Formato | |
---|---|---|---|
719791_thesis_-_calibration_of_the_neuland_detector_for_the_r3b_experiment_at_gsi.pdf
non disponibili
Tipologia:
Altro materiale allegato
Dimensione
7.8 MB
Formato
Adobe PDF
|
7.8 MB | Adobe PDF |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.14240/11258